Solar Heat Pump For Industrial Water Heating

Your Professional Solar Heat Pump for Industrial Water Heating Supplier

 

Solar-assisted heat pump systems designed for industrial and commercial hot water production, featuring published models with rated heating capacities from 75.5 to 172.5 kW.

 

These systems integrate a high-efficiency heat pump refrigeration circuit with photovoltaic power input. Operating via 380V, 50/60Hz AC grid power and 200–560V DC solar input, the equipment utilizes EVI DC inverter compressors and tank-side heat exchangers to supply stable hot water while lowering traditional grid energy consumption. Water connections range from DN50 to DN80, with water flow capacities spanning 13 to 29.7 m³/h.

 

 
 
Industrial Solar Heat Pump Models
 

Model

Rated Heating Capacity

Rated Heating Power

COP at Rated Heating

Recommended PV Power

Water Flow

Water Connection

LSQS66R2/BP-CP

75.5 kW

20.68 kW

3.65

22 kW

13 m³/h

DN50

LSQS75R2/BP-CP

86.1 kW

24.46 kW

3.52

24 kW

14.8 m³/h

DN50

LSQS150R2/BP-CP

143.3 kW

40.15 kW

3.57

40 kW

24.6 m³/h

DN65

LSQS190R2/BP-CP

172.5 kW

49.15 kW

3.51

48 kW

29.7 m³/h

DN80

 

Key Technical Specifications
 

Parameter

Industrial Specification Range

Heating Capacity

75.5 to 172.5 kW

Rated Power Input

20.68 to 49.15 kW

COP Range

3.51 to 3.65

AC Power Supply

380V, 50/60Hz

Solar DC Input

200 to 560V

Recommended PV

22 to 48 kW

Compressor Type

EVI DC Inverter

Refrigerant

R410 / R32

Water Flow Rate

13 to 29.7 m3/h

Water Connection

DN50 to DN80

Unit Noise Level

Less than or equal to 71 to 73 dB(A)

Approximate Weight

690 to 1,100 kg

 

Main System Configuration

 

Hybrid Solar Heat Pump System

PV Power Input Architecture

Supports 200–560V DC solar input, requiring a 22–48 kW photovoltaic array depending on the thermal model. The array layout should align with heat-pump electrical draws and local irradiation data.

Residential Solar Heat Pump for House

EVI DC Inverter Compression

Employs Enhanced Vapor Injection (EVI) inverter compressors. This modulation allows dynamic capacity tracking under changing ambient temperatures without constant on/off cycling.

Solar Powered Heat Pump System

Tank-Side Heat Exchangers

Optimized for high-volume water heating, utilizing reliable heat exchange interfaces designed for steady thermal transfer and reduced scaling potential.

 

Industrial Water Heating Applications

Factory Hot Water & Process Preheating: Continuous or batch hot water for production lines, equipment washing, and boiler feed-water preheating.

 

Hotels & Resorts: High-capacity hospitality sanitation and bathing demands, coupled with thermal storage to balance peak load hours.

 

Hospitals & Healthcare Facilities: Multi-stage hot water setups combined with storage tanks and continuous circulation loops to meet strict sanitary standards.

Commercial Laundries

Predictable, high-volume daily water consumption profiles ideal for high-COP thermal recovery.

Food Processing

Sanitary washing and cleaning operations requiring precise water temperature regulation.

Agricultural Facilities

Livestock climate control, greenhouse systems, and agricultural washing applications.

 

Residential Solar Heat Pump for House

 

System Working Principle & Operational Logic

An industrial solar heat pump transfers ambient heat into a water circuit while utilizing photovoltaic electricity as a primary power source.

 

Refrigeration Cycle: The system extracts environmental heat via the evaporator, elevates temperature using an EVI DC inverter compressor, and transfers thermal energy to water through a heat exchanger.

 

Energy Integration: Photovoltaic DC generation directly offsets compressor and auxiliary component electricity demand. When solar availability drops, the system seamlessly blends or switches to 380V AC grid power.

 

Control Strategy: Integrated controllers manage priority sequences—optimizing solar utilization, maintaining precise outlet water temperatures, and operating backup elements automatically.

 

 

System Accessories and Matching Equipment

An industrial heat-pump installation requires proper hydraulic and electrical balancing. Procurement teams should verify compatibility with:

 

Storage Tanks: Insulated buffer tanks to decouple heat generation from peak consumption.

 

Water Circulation Pumps: Sized to match internal pressure drops (less than or equal to 35 to 50 kPa) and flow requirements (13 to 29.7 m3/h).

 

Expansion Vessels and Safety Valves: To accommodate thermal expansion and maintain system pressure limits.

 

Water Treatment Systems: Softening or filtration units to protect heat exchangers from scaling in hard-water regions.

Hybrid Solar Heat Pump System

 

How to Select the Right Industrial Solar Heat Pump
 

Calculate Thermal Load

Determine total daily hot water consumption, peak hourly demand, and temperature rise.

Define Water Temperatures

Document accurate cold water inlet and target hot water outlet temperatures.

Verify Electrical and PV Specs

Confirm 380V AC supply availability and match the recommended 22 to 48 kW DC solar array.

Evaluate Hydraulics

Ensure pipe diameters (DN50 to DN80) and pump heads match system layouts.

 

Quality Control and Pre-Shipment Checks

Industrial units undergo strict factory testing covering:

Refrigerant circuit pressure testing and charge verification

01

Electrical wiring insulation and component check

02

Inverter controller and EVI valve response testing

03

Water-side pressure drop and heat-exchanger leakage checks

04

Vibration, noise level, and operational current profiling

05

 

 

Packaging and International Shipping

Prepared for global ocean and land freight logistics:

Hybrid Solar Heat Pump System

Heavy-duty structural base frames with protective crating

Solar Powered Heat Pump System

Secure lifting points and waterproof component wrapping

Residential Solar Heat Pump for House

Complete technical documentation, wiring diagrams, and nameplate verification included in export packages

 

 

Frequently Asked Questions

 

Q: What heating capacity do these industrial solar heat pumps deliver?

A: The current lineup ranges from 75.5 to 172.5 kW per single unit. Larger industrial loads can be met by paralleling multiple units.

Q: How does the system operate when solar radiation is low?

A: The equipment automatically supplements or transitions to 380V AC grid power, ensuring uninterrupted hot water delivery.

Q: What water connections and flow rates are featured?

A: Connections range from DN50 to DN80, supporting water flow rates between 13 and 29.7 m3/h.

Q: What data is required to get an accurate quotation?

A: Provide your inlet and outlet water temperatures, hourly or daily water volume, local power configuration, and available PV setup.

As one of the leading solar heat pump for industrial water heating manufacturers and suppliers in China, we offer a wide range of products with superior quality. Please feel free to wholesale customized solar heat pump for industrial water heating from our factory. Welcome to view our website for more information.

heat pump and solar panels, solar hot water with heat pump booster, Solar Powered Heat Pump System